Calculation
The additional rules by sector
Some sectors carry rules of their own, and those rules override the general choice of method. They also publish six figures a producer can use directly, each one the minimum the annex allows.
The figures the annex publishes for these sectors
Every figure below carries the decimal comma the Official Journal uses, so 0,525 means nought point five two five. Each is the minimum the annex sets, and in most cases the annex also describes a better figure an operator can establish for itself.
| What it applies to | The published figure | Provision |
|---|---|---|
| Desulphurisation calculated from the gypsum producedThe factor is the stoichiometric ratio of dry gypsum to the carbon dioxide emitted. The alternative, which the annex gives first, calculates from the carbonate consumed. | 0,2558 tonnes of carbon dioxide per tonne of gypsum | Point B.9.1.1 |
| Urea used as a reduction agent in a unit that removes nitrogen oxidesThe factor is the stoichiometric ratio, and the calculation follows the method based on the input. | 0,7328 tonnes of carbon dioxide per tonne of urea | Point B.9.1.2 |
| Flare gas, where more accurate monitoring is out of reachThe factor comes from the combustion of pure ethane, which the annex uses as a conservative proxy for flare gases. It applies where more accurate monitoring is not technically feasible or would cost too much. | 0,00393 tonnes of carbon dioxide per normal cubic metre | Point B.9.1.3 |
| Cement clinker, where emissions are determined from the clinker producedThe figure is the minimum requirement for the emission factor under the output based method. | 0,525 tonnes of carbon dioxide per tonne of clinker | Point B.9.2.2 |
| Cement kiln dust and bypass dust leaving the kiln systemThe figure is the minimum requirement. The improvement the annex recommends determines the factor at least once a year from the factor for clinker and the degree of calcination of the dust. | 0,525 tonnes of carbon dioxide per tonne of dust | Point B.9.2.3 |
| The oxygen fraction of dry air, used to calculate the flue gas flow in nitric acid productionThe flue gas flow is the total input air flow multiplied by one less the oxygen fraction of dry air, divided by one less the oxygen fraction of the flue gas. | 0,2095 by volume | Point B.9.3.2 |
What counts as a combustion emission
Combustion emissions cover every carbon dioxide emission from burning a fuel that contains carbon, waste included, whatever else that emission or that fuel is classified as. Where it is unclear whether a material acts as a fuel or as a process input, as it can be where a material reduces a metal ore, its emissions are monitored as combustion emissions.
Every stationary combustion unit is considered. The annex names boilers, burners, turbines, heaters, furnaces, incinerators, calciners, kilns, ovens, dryers, engines, fuel cells, chemical looping combustion units, flares, and thermal and catalytic post-combustion units.
The monitoring also takes in the process emissions from scrubbing the flue gas, which are the carbon dioxide from limestone or another carbonate used for desulphurisation and similar scrubbing, and the carbon dioxide from urea used in a unit that removes nitrogen oxides.
Flares, and what has to be counted
The calculation covers routine flaring and operational flaring alike, and operational flaring takes in trips, start-up, shut-down and emergency relieving. The carbon dioxide already present in the flared gases is included.
The improvement the annex recommends is a factor of the installation’s own, derived from the molecular weight of the flare stream by process modelling with industry standard models, producing a weighted annual average for that weight from the proportions and the molecular weights of the contributing streams. For the activity data of a flare, a higher measurement uncertainty is acceptable than for other fuels burned.
Cement clinker, by the input or by the output
Where the process emissions are determined from what goes into the kiln, two rules attach. Where cement kiln dust or bypass dust leaves the kiln system, the raw material behind that dust is not counted as a process input, and the emissions from the dust are calculated separately. Either the raw meal as a whole or the separate input materials may be characterised, so long as returned or bypassed material is neither counted twice nor left out. Where the activity data rests on the clinker produced, the net raw meal may be determined by a site specific empirical ratio of raw meal to clinker, and that ratio is updated at least once a year following industry best practice.
Where the process emissions are determined from the clinker produced, the clinker is weighed directly, or it is derived from cement deliveries by a material balance that accounts for clinker supplied, clinker dispatched and the change in clinker stock, using the ratio of clinker to cement. That ratio is derived for each cement product from laboratory analyses, or calculated from the difference between cement deliveries and stock changes and every material added to the cement, bypass dust and cement kiln dust included.
Nitric acid, where the gas is not carbon dioxide
Nitrous oxide is determined by a measurement based methodology. The concentration in the flue gas of each emission source is measured at a representative point, after the abatement equipment where abatement is used, and the technique used has to be able to measure the concentration of every emission source while abatement is running and while it is not. Every measurement is adjusted to a dry gas basis where that is needed, and reported consistently.
The flue gas flow follows the mass balance method, unless that is not technically feasible, in which case another method may be used, among them a mass balance on a significant parameter such as the ammonia input load, or a continuous measurement of the flow. The total input air flow is the sum of every air flow entering the nitric acid production unit, which takes in the primary and secondary input air and the seal input air where that applies.
When carbon dioxide counts as not emitted
Carbon dioxide already contained in a gas transferred into an installation, among them natural gas, a waste gas such as blast furnace gas or coke oven gas, and a process input such as synthesis gas, is included in the emission factor of that source stream. Where carbon dioxide contained in a gas transferred out is then emitted, by venting or by flaring, it counts as an emission of the installation it came from.
Carbon dioxide of fossil origin may be accounted for as not emitted in two cases. The first is where it is used within the installation or transferred to an installation that captures it, to an installation or transport network for long term geological storage, or to a storage site for long term geological storage under conditions equivalent to those in Union law. The second is where it is used within the installation or transferred to an entity that produces products in which the carbon is permanently chemically bound, so that it does not enter the atmosphere under normal use, including any normal activity after the end of the life of the product. In every case the receiving installation or entity monitors its emissions for the purposes of this regulation.
The deduction is allowed only so far as the evidence runs. It has to cover the whole chain of custody to the storage site or the installation of use, transport operators included, and it has to show the fraction of the carbon dioxide actually stored or used against the total transferred out of the originating installation.
The monitoring rules follow. The responsible person at each receiving installation or entity, and at each installation or entity carbon dioxide was received from, is named with contact details in the monitoring plan, and the amounts counted as not emitted and received are reported in the emissions report. The quantity transferred from one installation to another is determined by a measurement based methodology. The amount permanently chemically bound in products is determined by a calculation based methodology, preferably a mass balance, and the chemical reactions applied with their stoichiometric factors are written into the monitoring plan.