Calculation
How electricity is treated
Electricity is a good in its own right under the mechanism, and it is also an input to every other good. The two roles follow different rules, and point D of Annex II to the implementing regulation sets both.
Imported electricity carries direct emissions only
For electricity imported into the customs territory of the Union, only direct emissions count, under point 2 of Annex IV to the regulation. The emissions are the quantity of electricity in megawatt hours multiplied by the emission factor in tonnes of carbon dioxide per megawatt hour.
Which emission factor applies to imported electricity
Point D.2 sets four possibilities, and they are read in order. The first is the specific default value for the third country, the group of third countries or the region within a third country. The second applies where no specific default value is available, and it is the carbon dioxide emission factor in the Union.
The third is an alternative default value. It applies where a country or a group of countries submits sufficient evidence, resting on official and public information, that its own factor is lower than the first two, and where the conditions of point D.2.3 are met.
The fourth is the actual embedded emissions, which an authorised CBAM declarant may use in place of a default value where the evidence in point D.2.4 shows that the four cumulative criteria in point 5 of Annex IV to the regulation are met, and where the calculation rests on data determined by the producer of the electricity.
How an alternative default value is established and when it starts to apply
A country that submits its datasets by 30 June of a year can have its default value amended, where the Commission considers the sources reliable, by 30 June of the following year where that is feasible. The amended value then applies to electricity imported during the year in which the datasets were provided.
A country that submits after 30 June faces a longer road. The amendment is made by 30 June of the second year following the year of submission where that is feasible, and the amended value applies to electricity imported during the year after the year of submission. Where the Commission manages the amendment in the following year and before the deadline for submitting CBAM declarations under Article 6 of the regulation, the amended value applies to the year of submission instead.
The alternative factor rests on the average of the yearly factors for the most recent five year period for which reliable data is available. The moving average starts with the current year minus two and runs back to the current year minus six, and it may start at the current year minus one where more recent reliable data exists.
What evidence allows actual emissions for imported electricity
Point D.2.4 names the document that proves each criterion, so a declarant can see in advance what it has to hold.
- For the power purchase agreement, contractual evidence of an agreement concluded directly between the authorised CBAM declarant and a producer of electricity in a third country for the physical delivery of electricity. The agreement has to be in force at the time of the import and has to cover at least the quantity claimed. Where it was concluded through an intermediary, the evidence has to show that one single contract was concluded between the three parties.
- For the connection, either a single line diagram showing a direct connection between the installation and the Union transmission system, or written documentation from the transmission system operator or another entity with access to the information, attesting that at the time of export, taken hour by hour, there was no physical network congestion at any point between the installation and that system.
- For the emission limit, data showing that the installation does not emit more than 550 grammes of carbon dioxide of fossil fuel origin per kilowatt hour of electricity.
- For the nomination, written documentation from the person who nominated the capacity or from the transmission system operator, showing the quantity nominated in the country of origin, the country of destination and each country of transit, and the period the nomination covers, together with data from a smart metering system showing that the matching production happened within the same measurement period. That period may not exceed one hour.
- For the verification, monthly interim reports carrying the evidence that the other criteria are met.
How electricity used to produce other goods is metered
Point D.3 settles two questions that decide the figure. The metering applies to real power rather than to apparent power, so only the active component is metered and the reactive power is disregarded. For the production of electricity, the activity level is the net electricity leaving the system boundaries of the power plant or the cogeneration unit, after the electricity consumed inside it has been subtracted.
How the indirect emissions of other goods are determined
Point D.4 gives three routes. The first is the average emission factor of the electricity grid of the country of origin, as made available under Annex IV to the regulation. The second is an alternative default value under point D.4.4, where sufficient evidence from official and public information shows the grid factor of the country of production to be lower. The third is an actual emission factor under points D.4.1 to D.4.3.
Where electricity is produced by burning fuel, other than by cogeneration, the factor is the emissions of the fuel mix and the process emissions from cleaning the flue gas, divided by the net electricity produced. The net electricity may include quantities produced from sources other than combustion. Where electricity is produced by cogeneration, the factor follows the cogeneration rules of Annex III.
One rule stops a cheap waste gas from lowering the figure. Where a waste gas forms part of the fuel mix, and its emission factor is higher than the standard emission factor of natural gas in the first table of point G, the standard factor for natural gas is used in place of the waste gas factor.
The alternative default value for indirect emissions follows the same timetable as the one for imported electricity, and it rests on the simple average of the factor for the most recent five year period before the reporting for which reliable data is available.
What evidence allows actual indirect emissions
Point D.4.3 sets two routes, and each has its own list. A direct technical link is shown by a single line diagram, by smart metering data showing that the electricity claimed was produced by the connected installation and when it was produced, by smart metering data showing that it was delivered within the same measurement period, which may not exceed one hour, to an installation producing a good listed in Annex I to the regulation, and, where the link joins several installations, by a contract between the operators requiring the delivery of at least the quantity claimed. Where both installations belong to the same legal entity, an intra-company off-take agreement requiring that delivery takes the place of the contract.
A power purchase agreement is shown by contractual evidence of an agreement concluded directly between the installation producing the goods and a producer of electricity in a third country for physical delivery, by smart metering data on the production and its period, by smart metering data showing that an equivalent amount was delivered within the same measurement period, which may not exceed one hour, and by written documentation of a physical grid connection between the two installations.
Four slips in the published text of point D
This library states what a text says. Four places in point D carry an error that a reader meets on the page, so they are recorded here with the reading date rather than corrected in silence. Each was read in the Official Journal text on 13 October 2026.
- Point D.2.1
- The paragraph breaks off in the middle of its last sentence, and the published text ends on a definite article where a noun should follow. Point 4.2.1 of Annex IV to the regulation, which that point applies, says the specific default values rest on the best data available to the Commission.
- Point D.2.3 and point D.4.4
- The words which and the are set without a space between them, three times in the first and three times in the second. The sentences are readable, and the slip is recorded here because a reader who searches the text for a phrase will not find it.
- Point D.4.2
- The word according is printed without its first letter o. The point sends the reader to point A.2.2 of Annex III, which carries the cogeneration rules.
- Point D.4.4
- The text says the five year average is calculated on the basis of equations 45 and 56, and the equations it then sets out are numbered 39 and 40. Equations 39 and 40 are the yearly emission factor and the moving average, which are the two the paragraph describes.