Calculation
How perfluorocarbons are monitored
Primary aluminium is the one category whose monitoring covers a gas other than carbon dioxide and nitrous oxide. Perfluorocarbons are released by anode effects, and the implementing regulation sets two methods for measuring them and publishes a factor for each technology.
What the monitoring covers
The monitoring covers the perfluorocarbons released by anode effects, including the fugitive emissions. Emissions that are not related to anode effects are determined by methods that follow industry best practice, and the annex names the guidelines of the International Aluminium Institute in particular.
The total is calculated from what can be measured in a duct or a stack together with the fugitive emissions, by dividing the emissions measured in the duct by the collection efficiency of that duct. The collection efficiency is measured at the same time as the emission factors of the installation are determined.
The two methods, and what each one records
Method A, which the annex calls the slope method, applies where the anode effect minutes per cell day are recorded. The emissions of tetrafluoromethane are the anode effect minutes per cell day, multiplied by the slope emission factor in kilograms divided by a thousand, multiplied by the production of primary aluminium in tonnes over the reporting period. The anode effect minutes per cell day are the frequency of anode effects multiplied by their average duration.
Method B, which the annex calls the overvoltage method, applies where the anode effect overvoltage is recorded. The emissions of tetrafluoromethane are the overvoltage coefficient, multiplied by the anode effect overvoltage per cell divided by the average current efficiency, multiplied by the annual production of primary aluminium, and multiplied by one thousandth. The overvoltage per cell is the integral of time multiplied by the voltage above the target voltage, divided by the duration of the data collection.
Under both methods the emissions of hexafluoroethane are the emissions of tetrafluoromethane multiplied by the weight fraction of hexafluoroethane, which the same tables publish.
The factors for the slope method
| Technology | Factor for CF4, in kilograms of CF4 per tonne of aluminium per anode effect minute per cell day | Factor for C2F6, in tonnes of C2F6 per tonne of CF4 |
|---|---|---|
| Legacy Point Feed Pre Bake (PFPB L) | 0,122 | 0,097 |
| Modern Point Feed Pre Bake (PFPB M) | 0,104 | 0,057 |
| Modern Point-Fed Prebake without fully automated anode effect intervention strategies for PFC emissions (PFPB MW) | No factor is published | No factor is published |
| Centre Worked Prebake (CWPB) | 0,143 | 0,121 |
| Side Worked Prebake (SWPB) | 0,233 | 0,280 |
| Vertical Stud Søderberg (VSS) | 0,058 | 0,086 |
| Horizontal Stud Søderberg (HSS) | 0,165 | 0,077 |
The factors for the overvoltage method
| Technology | Factor for CF4, in kilograms of CF4 per tonne of aluminium per millivolt | Factor for C2F6, in tonnes of C2F6 per tonne of CF4 |
|---|---|---|
| Centre Worked Prebake (CWPB) | 1,16 | 0,121 |
| Side Worked Prebake (SWPB) | 3,65 | 0,252 |
The one technology with no published factor
The operator determines the factor by its own measurements. Where that is not technically feasible, or where it incurs unreasonable costs, the values for the centre worked prebake technology are used. The technology is the modern point fed prebake without fully automated anode effect intervention strategies.
When an installation has to measure for itself
The published factors are the minimum requirement under both methods. The improvement the annex recommends is a factor of the installation’s own, established by continuous or intermittent field measurements following industry best practice, and again the annex names the guidelines of the International Aluminium Institute.
Three conditions attach to a factor of the installation’s own. It takes account of the emissions that are not related to anode effects. It is determined to a maximum uncertainty of 15 per cent either way. It is determined at least every three years, and sooner where a relevant change at the installation calls for it, which includes a change in the distribution of anode effect duration and a change in the control algorithm that affects the mix of the types of anode effect or the nature of the termination routine.
How the two gases become one figure
The emissions in carbon dioxide equivalent are the tetrafluoromethane emissions multiplied by their global warming potential, plus the hexafluoroethane emissions multiplied by theirs. Both potentials are published in point G of the annex, and they are on the page of standard factors.